Voltage converters with regulation, time delay, power cut-off, and surge suppressor.
Application
Mainly used in industrial and commercial refrigeration equipment, and air conditioning and requires complete protection of the equipment and the installation against constant or eventual insufficiencies of the electrical supply.
Use
Domestic, commercial, and industrial.
Main Features
- Integral protection against a wide variety of electrical problems.
- High reliability and energy efficiency.
- Compact, robust, and industrial quality.
- For severe voltage conditions.
- High tolerance to electrical noise, reliable operation even in critical industrial environments.
- High-quality components and raw materials.
- Low power consumption.
- High operational safety.
- Robust cabinet in high mechanical resistance steel sheet, compact design, and electrostatic paint finish.
- UL or NOM-certified components.
- NOM-03 certification.
- ISO-9001 certification.
Nominal voltage Vac |
Frequency Hz |
Operating range Vac |
Output range Vac |
Line length Centimeters |
120 |
60 |
120 |
220 |
180 |
220 |
60 |
220 |
120 |
180 |
Operation
- Voltage conversion and regulation. Regulates the input voltage and converts it up to 220Vac (120/220Vac input models), or down to 120Vac (220/120Vac input models) at 60Hz.
- Indicadores LED:
- Green LED (1): indicates that the regulator is on..
- Yellow LED (2): lights up when the device is regulating high voltages.
- Yellow LED (3): lights up when the device is regulating low voltages.
- Red Led (4): shows that the device is in Delay/Wait which shows that the line voltage is out of the operating range.
Technical specifications
- Power factor: depends on the load.
- Minimum response time: 3 cycles.
- Operating temperature: 0-65°C at full load for 60 minutes.
Environmental specifications
- Operating temperature: 0-50ºC.
- Maximum operating altitude: 2500m above sea level
- Relative humidity: <93% non-condensing.
Insulation
Autotransformer impregnated in high vacuum and baked with class "H" dielectric varnish with a dielectric strength of 4,884V/mm (ASTM-D-115-55) dry and 3,030V/mm wet (salt chamber). Each product is insulation tested to 1,250Vac.
Complies with HiPot test at 1,250Vac.
Note: Typical operating ranges depend on each model.
Voltages: 120V a.c. and 220V a.c.
Powers: 500, 750, 1,000, 1,500, 1,500, 1750, 2,000, 2,500 and special.
Frequency: 60Hz
Input: NEMA L5-30P plug.
Output: NEMA L6-20R contact.
We also manufacture special designs according to your specifications.
WHY USE PROTECTION SYSTEMS?
- More than 65% of equipment failures are caused directly or indirectly by power supply deficiencies.
- Ensures safety: Surge protection mitigates risk and sudden failures, ensuring reliable operation.
- Increases service life: Protecting against surges, prevents certain incidents, thus extending the service life of equipment.
Given the voltage conditions in Latin America, integrating Kleinstad protection equipment is essential to achieve rational energy consumption, regardless of protection issues to the equipment.